hpicfFfDisablePortTolerance 1.3.6.1.4.1.11.2.14.11.1.7.1.1.4

The tolerance level used to calculate the port disable threshold for this fault type. The value of an instance of this object MUST be greater than the value of the corresponding instance of the hpicfFfWarnTolerance. The agent will periodically check relevant statistics for each port for each type of fault. If the port disable threshold has been exceeded, and port disable is enabled for that fault type, an hpicfFaultFinderTrap notification will be sent. In addition, an entry will be made in the hpicfFfLogTable for the fault. Ports will not be disabled until at least one polling interval after a warning has fired. In addition, the agent may further delay disabling a port in certain situations. For example, it may choose to delay disabling a cascade port to give the cascaded device a chance to correct the problem.

Informations

Access Type
readwrite

Parent

1.3.6.1.4.1.11.2.14.11.1.7.1.1 hpicfFfControlEntry