hrdevicestatus
1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.5
The current operational state of the device
described by this row of the table. A value
unknown(1) indicates that the current state of the
device is unknown. running(2) indicates that the
device is up and running and that no unusual error
conditions are known. The warning(3) state
indicates that agent has been informed of an
unusual error condition by the operational software
(e.g., a disk device driver) but that the device is
still 'operational'. An example would be high
number of soft errors on a disk. A value of
testing(4), indicates that the device is not
available for use because it is in the testing
state. The state of down(5) is used only when the
agent has been informed that the device is not
available for any use.
Refer to RFC 1514, Host Resources MIB, for more details.
Additional information:
The printer's condition is mapped as follows:
eHrunning -- Printer ready to print or is printing.
May be in power save mode.
eHwarning -- A condition exists that needs attention but it is
not currently preventing printing. A non-critical alert is
active.
eHtesting -- Printer is continuously printing a configuration page.
eHdown -- Printer is not printing due to an error condition. A
critical alert is active, human interaction is needed to bring the printer to
a ready state or the printer is offline.