wfSyncBurstCount
1.3.6.1.4.1.18.3.4.5.1.17
Allows control over the DMA burst cycle duration on MK5025 based products.
This attribute is ignored for AN and ASN products. The default is always
8 short word bursts (ENABLED). There are only two cases in which this
attribute should be changed.
Case 1: In certain cases with DSDE and DSE link modules when one or both
of the ethernet ports are suffering from excessive TxUflo or RxOflo
errors, the BurstCount of one or both SYNC interfaces can be set to
single short word bursts (DISABLED). The only modules for which this
may be necessary are the DSDE (5430 - Dual Sync, Dual Enet) (module ID
112) and the DSE (5420 - Dual Sync, Single Enet) (module ID 116).
If after making the change, the TxUflo or RxOflo errors persist on the
ethernet or this SYNC interface starts to get UnderFlowTx or OverFlowRx
errors, then the Link Module is overloaded and a more significant
software configuration change or a hardware configuration change is
needed.
Case 2: When a SYNC interface on an mk5025 based Link Module is getting
UnderFlowTx or OverFlowRx errors while running at bandwidths greater
than 2Mbps, the errors may be eliminated by setting this attribute to
unlimited burst mode (UNLIMITED). If after making the change, the
errors persist or the same errors start on another SYNC interface or
one of the ethernet interfaces on the same module starts to get TxUflo
or RxOflo errors, then the Link Module is overloaded and a more
significant software configuration change or a hardware configuration
change is needed. For 6Mbps full duplex operation, this attribute
will most likely need to be set to UNLIMITED and all other interfaces
on this module will most likely have to be deconfigured.