extremePethSlotPoeStatus 1.3.6.1.4.1.1916.1.27.1.2.1.8

Describes the status of the PoE system on the slot. initializing - PoE controller is under initialization, operational - PoE controller is operational and is ready or providing power, downloadFail - PoE controller required update and the update failed, PoE reset is required to re-update, calibrationRequired - PoE contoller is operational, however calibration is required to provide power, invalidFirmware - PoE controller contains invalid firmware, mismatchVersion - PoE controller update completed, however version mismatches expected, reboot, updating - PoE controller is being updated, invalidDevice - PoE controller detected an invalid/bad PoE device. notOperational - PoE controller is not yet operational other - PoE controller is in undefined stats.

Informations

Access Type
readonly initializing(1), operational(2), downloadFail(3), calibrationRequired(4), invalidFirmware(5), mismatchVersion(6), updating(7), invalidDevice(8), notOperational(9), other(10)

Parent

1.3.6.1.4.1.1916.1.27.1.2.1 extremePethPseSlotEntry