Sets the violation precedence for the specified ports. A value of
advertised-class will remove/deny power in the case an 802.3af compliant
PD consumes power beyond its advertised class limit. A value of
operator-limit will remove/deny power should the PD consume power
beyond the configured operator-limit. A value of max-class-operator will
remove/deny power if the PD consumes power beyond the maximum of the
detected class limit and the operator-limit. A value of none will
remove/deny power in case the PD device exceeds the maximum allowable
wattage according to regulatory maximum of 20 W. Default is
max-class-operator which allows operation of both 802.3af compliant and
legacy PDs.