hwMinMProtectApsFastInterval 1.3.6.1.4.1.2011.5.25.133.1.1.2.3.1.1.17

Indicates the configuration of fast sending time interval for each protection group. The time intervals for fast sending of Aps packets described in the G.8031 are as follows: By default, the time interval for fast sending of Aps packets in G.8031 is 3.3 ms. Optional values for sending interval are as follows: ApsInterval3dot3ms(1): indicates a sending interval of 3.3 ms. ApsInterval5ms(3): indicates a sending interval of 5 ms. ApsInterval10ms(3): indicates a sending interval of 10 ms. ApsInterval5ms(4): indicates a sending interval of 15 ms. ApsInterval20ms(5): indicates a sending interval of 20 ms. ApsInterval30ms(6): indicates a sending interval of 30 ms.

Informations

Access Type
readwrite

Parent

1.3.6.1.4.1.2011.5.25.133.1.1.2.3.1.1 hwMinMMacTnlApsCfgEntry