hwOspfv2LsaOrigHoldIntvl 1.3.6.1.4.1.2011.5.25.155.3.1.14

This object indicates the Holdtime interval of intelligent-timer for updating OSPF LSAs. After an intelligent timer is enabled, the interval for updating LSAs is as follows: The initial interval for updating LSAs is specified by the parameter start-interval. The interval for updating LSAs for the nth (n>2) time is equal to hold-interval*2(n-1). When the interval specified by hold-interval*2(n-1) reaches the maximum interval specified by max-interval, OSPF updates LSAs at the maximum interval for three consecutive times. Then, OSPF updates LSAs at the initial interval specified by start-interval. When hwOspfv2LsaOrigHoldIntvl is specified, you need also specify hwOspfv2LsaOrigMaxIntvl and hwOspfv2LsaOrigStartIntvl, but you cannot specify hwOspfv2LsaOrigIntvl. Note that -1 is not a configurable value. Instead, by set the intelligent timer to default value, it will get back to default configuration.

Informations

Access Type
readwrite

Parent

1.3.6.1.4.1.2011.5.25.155.3.1 hwOspfv2ProcessEntry