hwOspfv2LsaOrigHoldIntvl
1.3.6.1.4.1.2011.5.25.155.3.1.14
This object indicates the Holdtime interval of intelligent-timer for updating
OSPF LSAs. After an intelligent timer is enabled, the interval for updating
LSAs is as follows: The initial interval for updating LSAs is specified by the
parameter start-interval. The interval for updating LSAs for the nth (n>2)
time is equal to hold-interval*2(n-1). When the interval specified by
hold-interval*2(n-1) reaches the maximum interval specified by max-interval,
OSPF updates LSAs at the maximum interval for three consecutive times. Then,
OSPF updates LSAs at the initial interval specified by start-interval. When
hwOspfv2LsaOrigHoldIntvl is specified, you need also specify
hwOspfv2LsaOrigMaxIntvl and hwOspfv2LsaOrigStartIntvl, but you cannot specify
hwOspfv2LsaOrigIntvl. Note that -1 is not a configurable value.
Instead, by set the intelligent timer to default value, it will get back to
default configuration.