cpqRackCommonEnclosureTempThreshold 1.3.6.1.4.1.232.22.2.3.1.2.1.7

This is the threshold temperature sensor setting in degrees celsius. This is the temperature in which the sensor will be considered to be in a tripped state this causing some action to occur depending on the type of the sensor. The action of temperature sensor threshold will be indicated by the cpqRackCommonEnclosureTempType item. If the type is blowout(5), then the temperature sensor will cause the fans to speed up. If the type is caution(9), then the temperature sensor is in a degraded state. If the type is critical(15), then the enclosure will be considered as in a failed state. If this value cannot be determined by software, then a value of -1 will be returned.

Informations

Access Type
readonly

Parent

1.3.6.1.4.1.232.22.2.3.1.2.1 cpqRackCommonEnclosureTempEntry