This specifies the type of this instance of temperature
sensor.
This value will be one of the following:
other(1)
Temperature threshold type could not be determined.
blowout(5)
If a blowout(5) temperature sensor reaches its threshold,
the fan or fans in the area of the temperature sensor will
increase in speed in an attempt to reduce the temperature
before a caution or critical threshold is reached.
caution(9)
If a caution(9) temperature sensor reaches its threshold, the
cpqRackServerTempSensorCondition will be set to degraded(3)
and the system will either continue or shutdown depending
on the local blade server policy settings.
critical(15)
If a critical(15) temperature sensor reaches its threshold,
cpqRackServerTempSensorCondition will be set to failed(4)
and the blade server will shutdown.