cpqHeTemperatureCondition 1.3.6.1.4.1.232.6.2.6.8.1.6

The Temperature sensor condition. This value will be one of the following: other(1) Temperature could not be determined. ok(2) The temperature sensor is within normal operating range. degraded(3) The temperature sensor is outside of normal operating range. failed(4) The temperature sensor detects a condition that could permanently damage the system. The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent. If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.

Informations

Access Type
readonly other(1), ok(2), degraded(3), failed(4)

Parent

1.3.6.1.4.1.232.6.2.6.8.1 cpqHeTemperatureEntry