This object specifies a configurable repetition time between
Measurement Intervals in a Loss Measurement session, in seconds.
If the value is 0 (none), there is no time gap between the end of one
Measurement Interval and the start of a new Measurement Interval.
This is the normal usage case.
If the value is greater than 0 but less than or equal to the measurement
interval, an error is returned.
If the value is greater than one Measurement Interval there is time gap
between the end of one Measurement Interval and the start of the next
Measurement Interval. The repetition time specifies the time between
the start of consecutive Measurement Intervals; hence the gap between
the end of one Measurement Interval and the start of the next is equal
to the difference between the repetition time and the measurement
interval. During this gap, no SOAM PDUs are sent for this session and
no measurements are made.
This object can only be written at row creation time and cannot be
modified once it has been created.