jnxSoamLmCfgRepetitionTime 1.3.6.1.4.1.2636.3.78.1.2.1.1.18

This object specifies a configurable repetition time between Measurement Intervals in a Loss Measurement session, in seconds. If the value is 0 (none), there is no time gap between the end of one Measurement Interval and the start of a new Measurement Interval. This is the normal usage case. If the value is greater than 0 but less than or equal to the measurement interval, an error is returned. If the value is greater than one Measurement Interval there is time gap between the end of one Measurement Interval and the start of the next Measurement Interval. The repetition time specifies the time between the start of consecutive Measurement Intervals; hence the gap between the end of one Measurement Interval and the start of the next is equal to the difference between the repetition time and the measurement interval. During this gap, no SOAM PDUs are sent for this session and no measurements are made. This object can only be written at row creation time and cannot be modified once it has been created.

Informations

Access Type
readonly

Parent

1.3.6.1.4.1.2636.3.78.1.2.1.1 jnxSoamLmCfgEntry