jnxSoamLmCfgAvailabilityNumConsecutiveMeasPdus
1.3.6.1.4.1.2636.3.78.1.2.1.1.31
This object specifies a configurable number of consecutive
loss measurement PDUs to be used in evaluating the
availability/unavailability status of each availability
indicator per MEF 10.2.1. Loss Measurement PDUs (LMMs, CCMs or
SLMs) are sent regularly with a period defined by
jnxSoamLmCfgMessagePeriod. Therefore, this object, when
multiplied by mefSoamLmCfgMessagePeriod, 2050 is equivalent to
is equivalent to the Availability parameter of 'delta_t' as
specified by MEF 10.2.1.
If the jnxSoamLmCfgType is lmLMM or lmCCM, this object defines the
number of LMM or CCM PDUs transmitted during each 'delta_t' period.
The Availability flr for a given 'delta_t' can be calculated based
on the counters in the last LMM/R or CCM during this 'delta_t' and
the last LMM/R or CCM in the previous 'delta_t'.
If the jnxSoamLmCfgType is lmSLM, this object defines the number
of SLM PDUs transmitted during each 'delta_t' period. The
Availability flr for a given 'delta_t' is calculated based on the
number of those SLM PDUs that are lost.
If the jnxSoamLmCfgType is lmLMM or lmCCM, the number range of 1
through 10 must be supported. The number range of 10 through 1000000
may be supported, but is not mandatory.
If the jnxSoamLmCfgType is lmSLM, the number range of 10 through
100 must be supported. The number range of 100 through 1000000
may be supported, but is not mandatory.
This object can only be written at row creation time and cannot be
modified once it has been created.