This table contains the list of Loss Measurement configuration threshold
values for LM Performance Monitoring.
The main purpose of the threshold configuration table is to configure
threshold alarm notifications indicating that a specific performance
metric is not being met.
Each row in the table represents a Loss Measurement session threshold
set for the defined MEP. This table uses five indices. The first three
indices are the indices of the Maintenance Domain, MaNet, and MEP tables.
The fourth index is the specific LM session on the selected MEP. The
fifth index is the specific threshold set number.
Rows in this table are not created automatically. A row is created in
this table to set up a threshold set on a configured MEP that has a
configured LM session.
If two managers try to 'create' the same row at the same time, the first
creation would succeed, the second creation attempt would result in an
error. The second creation attempt would then need to select a new index
value to successfully create a new row.
An NE needs to support at least one threshold set for NE SOAM PM compliance. A
second threshold set on the NE is desirable. More than two threshold
sets can be configured on the NE if supported on the NE.
All the objects in the row have a default value that disables the
particular threshold measurement. In order to enable a threshold
measurement the particular bit in the jnxSoamLmThresholdCfgEnable object
is to be set to '1' and the selected threshold measurement is to have
a threshold value configured. Non-configured threshold measurements
are disabled by default.
The writable objects in this table need to be persistent upon reboot
or restart of a device.