This attribute controls how a PPP trunk starts up. It is used to indicate
if this is an inband managment trunk. TRUE indicates the trunk can be
exclusively used for inband managment. FALSE indicates the trunk is a data
trunk only. A PPP trunk can not be used for inband managment and data
passing at the same time. The default for this attribute is FALSE