lpEngArcOvTotalConnectionPoolCapacity
1.3.6.1.4.1.562.2.4.1.12.23.5.2.10.1.1
This attribute specifies the maximum number of connections (VCC,
VPC, and VPT) that can be enabled on this FP. A standard Vpt uses
3 connections and a basic Vpt uses 2.
If the LogicalProcessor is associated with a card of a cardType
other than one of the following: 3pE3Atm, 3pDS3Atm,
3pOC3MmAtm, 3pOC3SmAtm, 3pE1Atm, 3pDS1Atm,
2pJ6MAtm; the value of the attribute restricts the sum of the
(maxVccs + maxVpcs + (maxVpts * 3)) across all AtmIfs bound to
this LogicalProcessor.
If the LogicalProcessor is associated with a card of one of the
following cardTypes: 3pE3Atm, 3pDS3Atm, 3pOC3MmAtm,
3pOC3SmAtm, 3pE1Atm, 3pDS1Atm, 2pJ6MAtm; the number of
available connections are distributed equally across the ports on the
FP. The number of connections associated to a particular port limits
the size of the Vcc space which can be defined by the ConnMap of
the AtmIf linked to the port. If the ConnMap component does not
exist, its default settings are used for this check. Furthermore, the
value of this attribute is restricted based on the number of ports on
the card. For one port cards, the minimum is 512, the maximum is
4096 and the value must be divisible by 256. For two port cards, the
minimum is 1024, the maximum is 8192 and the value must be
divisible by 512. For three port cards, the minimum is 1536, the
maximum is 7680 and the value must be divisible by 768.
If the LogicalProcessor is associated with a card of one of
the following cardTypes: 8pE1Atm, 8pDS1Atm, the
maximum value for this attribute is 10752.
For SGAF cards, the Connmap attributes are set to their default
values.
Increasing the value of this attribute reduces the memory available
for cell and frame memory.
This attribute must be set to 0 if the connectionPoolCapacity
attribute of the Arc Ov component is set to non-zero values.