lpE3RxRaiAlarm 1.3.6.1.4.1.562.2.4.1.12.6.16.1.4

This attribute displays whether a Remote Alarm Indication (RAI) alarm state has been entered. A RAI alarm state is entered when far- end SEF/AIS defects (or Far-End Receive Failure (FERF) defects in G.832 E3 Framing mode) have been observed and accumulated for a period of 2.5 seconds +/- 0.5 seconds on the E3 incoming line. If the RAI defects are intermittently occurring, the RAI defect accumulator is decremented at a rate of 1/10 of the incrementing rate (alarm integration ratio of 1/10), with all measurements based on a 200 ms polling cycle. The E3 component goes into an operational state of disabled until the RAI alarm condition is cleared. The condition is cleared when the far-end defect indicator has not been detected for 10 seconds +/- 0.5 seconds. The declaration of a RAI Alarm is usually a signal that the far end facility is unable to gain synchronization. The rxRaiAlarm attribute is always set to off when the component has been locked and left offline.

Informations

Access Type
readonly on(0), off(1)

Parent

1.3.6.1.4.1.562.2.4.1.12.6.16.1 lpE3OperEntry