mscAtmIfCACbrUsageParameterControl
1.3.6.1.4.1.562.36.2.1.114.3.2.100.1.170
This attribute specifies the default usage parameter control (UPC)
option for connections of the CBR service category. This attribute is
ignored if the rxTrafficDescriptorType indicates 1 or 2. An override
to this default may be specified for a provisioned connection under
the Vcd Tm or Vpd Tm component.
When this attribute is set to enforced, UPC is enforced by default
for each connection. When UPC is enforced, non-conforming cells
are either tagged or discarded depending on the
rxTrafficDescriptorType.
On ATM IP FPs, when this attribute is set to monitored, UPC
conformance checking is performed, except, instead of the non-
conforming cells being tagged or discarded, they are merely
counted in the UPC violations counts, and passed on unchanged.
On CQC-based ATM FPs, when this attribute is set to monitored, it
has the same effect as setting it to disabled.
When this attribute is set to disabled, UPC is disabled on the receive
path for all CBR connections.
This attribute never applies to any type of Vpt.