mscLpDS1LosAlarm
1.3.6.1.4.1.562.36.2.1.12.7.16.1.1
This attribute displays whether a LOS (Loss of Signal) alarm state
has been entered. A LOS alarm is declared after LOS defects have
been observed and accumulated for a period of 2 seconds +/- 0.5
seconds (for 3pDS1Atm, 3pE1Atm, 8pDS1Atm, and 8pE1Atm
cards: 2.5 seconds +/- 0.5 seconds). A LOS defect is detected upon
observing all zeros for 150 ms (for 3pDS1Atm, 3pE1Atm,
8pDS1Atm, and 8pE1Atm cards: upon observing 175 +/- 75 pulse
positions with no pulses of either positive or negative polarity). If
the LOS defects are intermittently occurring, the LOS defect
accumulator is decremented at a rate of 1/10 of the incrementing
rate (alarm integration ratio of 1/10), with all measurements based
on a 200 ms polling cycle.
The port goes into an operational state of disabled until the LOS
alarm state is cleared. Also, an RAI alarm is transmitted to the far
end for the duration of the LOS alarm state.
The LOS alarm state is cleared when LOS defects are absent for 10
seconds +/- 0.5 seconds.