mscLpV35LinkMode
1.3.6.1.4.1.562.36.2.1.12.9.10.1.1
This attribute defines the intended gender of the V.35 interface. The
actual gender of the interface is determined by the physical
connection to the patch panel. If the hardware setup does not match
this attribute, an alarm will be generated.
In dte mode, the RTS line signal is driven as specified by the
attribute readyLineState when the interface passes its initial
diagnostics. Then, the RTS line signal will be driven as specified in
the attribute dataTransferLineState when the application is ready to
transfer data. On the other hand, the input line signals (RFS, DSR,
and DCD) are compared against those specified in the attributes
readyLineState and dataTransferLineState. The application will be
notified when the specified input line states are observed.
In dce mode, the V35 component behaves similarly as when it is in
dte mode. However, it will be driving the DCE line signals (RFS,
DSR, and DCD) and monitoring the DTE line signal (RTS) as
specified by the attributes readyLineState and
dataTransferLineState.