mscVctDcType
1.3.6.1.4.1.562.36.2.1.5130.3.10.1.6
This attribute specifies the type of Vc call:
switched,
permanentMaster,
permanentSlave,
permanentSlaveWithBackup,
permanentBackupSlave,
spvcMaster,
spvcSlave,
spvcSlaveWithBackup,
spvcBackupSlave.
If the value of this attribute is set to switched then the remote end
must also be provisioned as switched. No information at the remote
end is defined about this switched interface.
If the value is set to permanentMaster, then a permanent
connection will be established between 2 ends. The remote end
must be defined as a permanentSlave, permanentBackupSlave or
permanentSlaveWithBackup. The connection cannot be established
if the remote end is defined as anything else. The end defined as
permanentMaster always initiates the calls. It will attempt to call
once per minute.
If the value is set to permanentSlave then a permanent connection
will be established between 2 ends. The remote end must be defined
as a permanentMaster. The connection cannot be established if the
remote end is defined as anything else. The permanentSlave end
will attempt to call once per minute.
If the value is set to permanentSlaveWithBackup then a permanent
connection will be established between the two ends. The remote
end must be defined as a permanentMaster. The connection cannot
be established if the remote interface end is defined as anything
else. The permanentSlaveWithBackup end will attempt to call once
per minute. When type is set to permanentSlaveWithBackup
connection will be cleared if interface becomes unavailable. This
enables a retry of the connection which can be redirected to
permanentBackupSlave.
If the value is set to permanentBackupSlave then a permanent
connection will be established between the 2 ends only if the
permanentMaster end is disconnected from the
permanentSlaveWithBackup end and a backup call is established
by the redirection system. If the permanentSlaveWithBackup
interface becomes visible again, the permanentBackupSlave end is
disconnected and the permanentSlaveWithBackup end is
reconnected to the permanentMaster end. The
permanentBackupSlave end does not try to establish pvc call.
If the value is set to spvcMaster, then a permanent connection will
be established between two ends, with resiliency at the NNI(s), if
the connection transits across two or more networks. The remote
end, which may be in the same network, or an external network that
is reachable via Frame Relay NNIs, must be defined as either a
spvcSlave, spvcBackupSlave or spvcSlaveWithBackup. The
connection cannot be established if the remote end is defined as
anything else. The end defined as spvcMaster always initiates the
calls. It will attempt to call once per minute. The call is attempted
by the spvcMaster, and accepted by the remote end, only if all three
of the following conditions are satisfied at both ends:
1. The datalink layer must be operational
2. The LMI procedures must be in normal condition (i.e. no service
affecting condition)
3. If the LMI side attribute is provisioned to both, the A-bit received
from the interface must be Active. If the LMI side attribute is not
provisioned to both, this condition does not apply.
After a call is cleared, the end defined as spvcMaster attempts to
retry the call according to the rule for the clear cause. If the call is
cleared or rejected due to the failure of one of the three conditions
indicated above, or due to unavailability of resources along any
point in the connection path, the call will be retried after 60
seconds. For all other causes, such as loss of service at an NNI, the
call will be retried immediately.
If the value is set to spvcSlave then a SPVC connection will be
established between two ends. The remote end must be defined as a
spvcMaster. The connection cannot be established if the remote end
is defined as anything else. The spvcSlave end never attempts to
call.
If the value is set to spvcSlaveWithBackup then a SPVC connection
will be established between the two ends. The remote end must be
defined as a spvcMaster. The connection cannot be established if
the remote interface end is defined as anything else. Unlike a
permanentSlaveWithBackup end, the spvcSlaveWithBackup end
never attempts to call. If the value is set to spvcSlaveWithBackup,
the connection will be cleared if the interface becomes unavailable.
This enables a retry of the connection by the spvcMaster end, which
may be redirected to an end that is set to spvcBackupSlave.
If the value is set to spvcBackupSlave then a SPVC connection will
be established between the two ends only if the spvcMaster end is
disconnected from the spvcSlaveWithBackup, end and a backup
call is redirected by the call redirection system. Unlike the
permanent connection, if the spvcSlaveWithBackup interface
becomes available again, the spvcBackupSlave end is not
disconnected and the spvcSlaveWithBackup end is not reconnected
to the spvcMaster end. Neither the spvcBackupSlave nor the
spvcSlaveWithBackup end try to establish a SPVC call.