mscFrUniSigHighestPvcDlci 1.3.6.1.4.1.562.36.2.1.71.6.11.1.1

This attribute specifies the highest DLCI value that can be provisioned for a PVC. It partitions the DLCI space into PVC and SVC. PVC DLCI numbers higher than this value are rejected. The value 0 is used to indicate that no PVCs are allowed on the interface. The value 1007 indicates that no SVCs are allowed on the interface.

Informations

Access Type
readwrite

Parent

1.3.6.1.4.1.562.36.2.1.71.6.11.1 mscFrUniSigRangeEntry