DURABLE:
The meanings of the values are:
enabled(1) - setting this object to enabled causes the
device to begin it's power up sequence and attempt to
enter its operational state. If the value of this object
was disabled, then the non-volatile value of this object
is changed to enabled. As part of the power up sequence,
the device's management parameters may or may not be
reset. (In other words, the device may go through the
equivalent of a reset or before returning to the online state.
If the device is capable of going directly from the disabled
state to the enabled state without resetting any of its
management parameters, then it may do so. Such action is
product specific.)
disabled(2) - setting this object to offline causes the
device to cease network activity and enter a quiescent
state. A disabled device must still be able to respond
to management messages.
The value enable(1) or disable(2) shall be stored
in non-volatile memory for the initial reset value
of this variable. The factory default NV value is enable(1).