Specifies the filter for event log messages. Valid
values are information, warning, and error.
The values are defined as follows:
none (1) Pass no messages. This is effectively
a disable condition for Event Logging.
information (2) Pass Informational Level, Warning Level
and Error Level messages.
warning (3) Pass Warning Level and Error Level
messages.
error (4) Pass Error Level messages only.