The current state of the interface shutdown functionality in
the Flow Limiting feature.
enabled (1) - Flow Limiting will shutdown an interface when
the conditions on that interface exceed the
configured values, one of the specified actions
is to disable the interface, and the Flow
Limiting feature is enabled.
disabled (2) - Flow Limiting will not shutdown any interface
under any conditions.
When this object is set to disabled the Flow Limiting feature
MUST release its control on all interfaces. Any interfaces
that had been operationally held in the 'down' state MUST be
allowed to attain their currently correct operational state.
Agents are not required to shutdown interfaces for conditions
that exist when this object is set to enabled. Interfaces
MAY only be shutdown after additional flow setups are detected
that exceed the configured limits on that interface.
Maintaining the value of this object across agent reboots is
REQUIRED.