The mean value of the randomized interval during which a
downstream router stops Register-encapsulation after receiving
a PIM Register-Stop message.
This object corresponds to the 'Register_Suppression_Time'
defined in PIM-SM [RFC 4601].
Note: Configuring different values for this object for
different routers in the PIM domain may lead to
incorrect protocol operation.