nbsCmmcPortTxPowerLevel 1.3.6.1.4.1.629.200.8.1.1.65

This object indicates whether this port has a problem with its transmitter power. If this port does not support SFF-8472 Digital Diagnostics, this value should be notSupported(1). If Digital Diagnostics indicate TxPower is below the low Alarm Threshold, this value should be lowAlarm(2). If Digital Diagnostics indicate TxPower is above the low Alarm Threshold but below the low Warning threshold, this value should be lowWarning(3). If Digital Diagnostics indicate this port is within the recommended operating range, value is ok(4). If Digital Diagnostics indicate TxPower is higher than the high Warning threshold, but has not crossed the Alarm threshold, this value should be highWarning (5),. If Digital Diagnostics indicate this port has crossed the high Alarm threshold, this value should be highAlarm(6). The related object nbsCmmcPortTxPower indicates what the current TxPower is.

Informations

Access Type
readonly notSupported(1), lowAlarm(2), lowWarning(3), ok(4), highWarning(5), highAlarm(6)

Parent

1.3.6.1.4.1.629.200.8.1.1 nbsCmmcPortEntry