Contents of device-level rising/falling threshold trap.
The format is as follows:
Octet 1: length including this octet (L)
Octet 2: number of threshold type/change pairs
Octets 3 - L: type/change pairs
each pair consists of one octet
identifying the threshold type
and one octet identifying the change
type.
Threshold type values:
Rx threshold = 1
RxTx threshold = 2
Backplane threshold = 3
VCC threshold = 4
HRE CAM threshold = 5
MPM CAM threshold = 6
Memory threshold = 7
CPUn threshold = 7 + n (1 <= n <= 4)
HRE collision threshold = 12
Change type values:
falling threshold change = 1
rising threshold change = 2
Only those thresholds for which a threshold
crossing event is detected will be present.
This object is not intended to be accessed directly.
It is defined for use in device-level rising/falling
threshold traps.