The scheduled date and time the switch will be
reset at. The system will only take octet strings
with length 8 for this object which indicates the
local time of the switch. The maximum scheduled
time is 24 days from the current system clock time.
Setting this object value to be before the current
system clock time or beyond the maximum scheduled
time limit will be rejected by the system. Setting
the object to all-zero octet strings will cancel the
previously scheduled reset time and then the system
will have no pending scheduled reset time. Setting
this object value to be any valid octet strings
other than the above cases will override the
previously scheduled reset time and cause the system
to be reset at the newly specified time.
After the system has accepted the scheduled reset
time, if the system clock is advanced ahead of the
scheduled reset time, then reset will happen
approximately 5 minutes after the current clock.