This object specifies whether trunk-condition is enabled.
The value 'true' means trunk-condition enable and the
value 'false' means trunk-condition disable.
If this object is set to 'true', gateway will apply
trunk conditioning on the DS0's of this DS1 interface
that are in alarm.
Trunk Conditioning - gateway will transmit idle code pattern
for the first 2.5 secs and then transmit seized code, both
idle code and seized code are specified by the 'ds0IdleCode'
and 'ds0SeizedCode' MIB objects in the CISCO-CAS-IF-EXT-MIB.
This object is applicable for trunking applications only.