This object and cGgsnThruputIntervalTwo specifies the
interval at which the data throughput needs to be
collected per APN/SGSN.
Once this object is set to some valid value, the data
throughput collections gets started for per configured
APN and per PATH created. The data throughput collection
is updated periodically (each expiry of configured throughput
interval) to the corresponding objects (cGgsnSgsnStatTable
for per SGSN and cgprsAccPtThruputStatsTable for per APN).
When this object is set to '0', the collection for this
interval get stopped and the data related to this interval
is deleted from the tables (cGgsnSgsnStatTable and
cgprsAccPtThruputStatsTable).
INCONSISTENT value SNMP error will happen when trying to set
cGgsnThruputIntervalOne and cGgsnThruputIntervalTwo with same
value expect '0'. Setting the same value to the same object
will reset the value / collection status for that interval.