Specifies how often PNNI polls resource management to
update the values of local interface metrics and
attributes.
The value of this object impacts the number of new
instances of PTSEs originated by this switching system. A
larger interval reduces the number of new instances of
PTSEs caused by interface traffic fluctuation. A smaller
interval allows PNNI to track traffic fluctuations more
quickly, at the expense of increased processing load.
In normal situations, this object should not be changed
from its default value. Care should be taken when
adjusting this parameter so as not to overload switch
processing.