This object specifies the maximum number of rows the
cfmAlarmHistoryTable can contain at any given time. If the
device raises or clears an alarm and the cfmAlarmHistoryTable
already contains a number of rows equal to the value of this
object, then it destroys the oldest row before creating a new
one.