cnsInpSrcMSW 1.3.6.1.4.1.9.9.761.1.1.3.1.19

This object indicates the manual switching flag. The 'true' value indicates the currently selected clock source is a result of the manual switching. The switch allows a user to select a synchronization source assuming it is enabled, not locked out, not in signal fail condition, and has a QL better than DNU in QL-enabled mode. A clock source is enabled when it occupies a row in cnsInputSourceTable. A clock source is not locked out when cnsInpSrcLockout contains the value 'false'. A clock source is not in signal failure condition when cnsInpSrcSignalFailure contains the value 'false'. The QL is identified in cnsInpSrcQualityLevel. In QL-enabled mode, a manual switch can be performed only to a source which has the highest available QL.

Informations

Access Type
readonly

Parent

1.3.6.1.4.1.9.9.761.1.1.3.1 cnsInputSourceEntry